1. Aluminium rafter capping.
2. High-performance glazing unit.
3. Aluminium glass end closure.
4. Timber rafter.
5. Roof lantern cill / plate.
6. Timber packer (Requirement depends upon kerb width).
7. Aluminium skirt.
8. Bull-nose detail.
9. 100mm wide upstand frame constructed from 100mm x 50mm timber.
10. 15mm exterior grade ply.
11. External weathering finish to individual preference.
12. 100mm Polyurethane insulation (Such as Celotex or Kingspan).
13. Insulated plasterboard.
14. Skim finish.
15. Angle fillet.
16. Flat roof construction
Items 13 & 14. to be completed after roof lantern installation.
Always consult appropriate professional advice to ensure compliance with local building regulations and standards before proceeding with construction.