Aluminium Roof Lantern Upstand Detail

Components supplied as part of the roof lantern:

1. Aluminium rafter capping.

2. Glazing unit.

3. Aluminium rafter closure.

4. Aluminium rafter.

5. Aluminium ringbeam / roofplate.

Typical supporting construction by others:

6. Optional inner timber cill

7. Supporting timber kerb/upstand.

8. Exterior-grade board/ply

9. External weatherproofing finish

10. Insulation

11. Internal plasterboard/lining

12. Internal finish

13. Flat roof construction

Important: The supporting construction shown above is illustrative only. The design, insulation, weatherproofing and internal finishing of the roof and upstand are the responsibility of the customer’s builder or roofing contractor and should be appropriate to the individual project.

The outside dimensions of the finished kerb/upstand are the critical dimensions for the roof lantern and must correspond with the approved order or drawing. The finished kerb should also be square, level and suitable for securely fixing the aluminium ringbeam.

Aluminium roof lantern kerb detail illustrating the critical dimension from the outside face of the finished kerb. A technical drawing from Just Roof Lanterns, showing the precise construction layers for accurate installation.